How can I run lighthouse for multiple pages/URLs without having to run the lighthouse-ci command multiple times for every single page I want to test/audit?
How I currently run my lighthouse tests for my pages.
lighthouse-ci --performance=80 --seo=80 --accessibility=80 --best-practices=80 <url-1>
lighthouse-ci --performance=80 --seo=80 --accessibility=80 --best-practices=80 <url-2>
lighthouse-ci --performance=80 --seo=80 --accessibility=80 --best-practices=80 <url-3>
I've had a lot of luck with Lighthouse Parade, another CLI package. It runs a Lighthouse report on all pages discoverable from the url you provide:
npx lighthouse-parade http://www.dfwfreeways.com/
Pro tip: run it at night or give it a limit on the number of pages to run if you're not familiar with how many pages are on a domain :)
instead of cli, you can write a program, where you can read urls from a file
you can use this for reference
https://github.com/gowthamraj198/Lighthouse
I came across the same problem and while looking for a good solution came across this nifty little package - lighthouse-batch
All I had to do was run the following by passing URL's separated by a comma:
lighthouse-batch -s https://www.url1.com,https://www.url2.com,https://www.url3.com
You also get the summary of all the sites passed in a single summary.json file as well as a detailed report for each site under the file site_url.json
I had the exact same issue. So I built a web tool for that: https://qualitycs.dev
It crawls sitemap to find new pages then it runs lighthouse regularly.
Issues are listed per page and globally. Meaning that you can directly see site wise issues such as cache, dans, https etc.
I'm actively working on it so new features are coming.
Related
I am using this tool to create a simple GUI with it's easy to understand set up: https://github.com/UniversalGUI/UGUI
But from what I understand from its guides that it needs executables to be in different names so that it can differentiate itself and the form sending it. The project I am doing needs me to use the same command but with different arguments such as:
<cmd executable="xdg-open">
<arg>/home/kali/Downloads/</arg>
</cmd>
I need to open other folders in different parts of the program using that executable. In the guides, the person did use an .exe file which I figured is a script included in its folder and I did try to replicate it but to no luck. https://www.youtube.com/watch?v=qHMRroZ7AAw
The tool isn't used by many but those who do, do you know how to get over this issue?
I've just installed Octave 7.1.0 and I noticed a strange sequence of error/warning messages which I had never seen before nor am able to decipher:
2022-05-06T16:59:34.366ZE [6832:ShellIpcClient] message_loop.cc:133:Run Run called on MessageLoop that's already been Quit!
2022-05-06T16:59:34.368ZE [12660:ShellIpcClient] message_loop.cc:133:Run Run called on MessageLoop that's already been Quit!
2022-05-06T16:59:34.369ZE [8132:ShellIpcClient] message_loop.cc:133:Run Run called on MessageLoop that's already been Quit!
2022-05-06T16:59:34.371ZE [15212:ShellIpcClient] message_loop.cc:133:Run Run called on MessageLoop that's already been Quit!
Since I haven't had the time to test this new version (a mere 1/2 hour has passed since I installed it) I cannot tell whether or not Octave's functionality is compromised.
Any ideas?
Wherever this message comes from, it is not from Octave. Someone reported the same issue last year on Octave's forum at Strange opening messages when opening Octave each time which links to a similar issue on the Far Manager bug tracker. The Far Manager devs suggest that this comes from Google drive:
When you open a context menu, all registered shell extensions are loaded into the Far process. These extensions implement custom context menu items, shown by various software. Sometimes the authors of these extensions add various debug logging messages to their code to see what is going on in various situations. Sometimes these authors are too lazy to implement a proper logging and they just print stuff to the standard output stream, connected to a console. Windows Explorer doesn't have a console attached to it, so all these messages go into the void. Far, on the contrary, does have a permanently attached console - you're looking at it. Therefore, any debug stuff these lazy people print in their extensions ends up in that console.
It's quite sad, but there's nothing we can do about it.
Please search for that string ("Run Run called on MessageLoop that`s already been Quit") in your Program Files folder and, once found, report to the corresponding product owners. I suspect that in your case it's Google Drive.
I am doing end-2-end testing with protractor. and for creating a report of all these test cases, I am using Protractor-html-reportor, Which create an .html file as report of all these test cases. All is good. What I want that after creating that html file(Report), At the end I want to run it automatically on browser. Thanks in Advance?
I have got answer from sqa.stackexchange site.
I have used grunt-open for it. It is working fine. But it have following warning every time, when it launch report.
The warning is in this question. I have not got any solution so far. But it is working fine, if you dont worry about that warning.
I am porting over an MSBuild script from CCnet to run in Jenkins. The MSBuild project is used to create a deployment package. I would rather have Jenkins drive this process itself but that's a longer term aim.
The problem i am having is (as in the title) when we try and use the HgPull target, from the MSBuild mecurial task (http://msbuildhg.codeplex.com/) we get the error message
HgProcessException: The command hg.exe is not available [Path to project]
I have seen on the project web site that someone solved it by adding the LibraryLocation proeprty to the target but that seems to have made no difference. My target currently looks like this:
Target Name="UpdateSources">
<HgPull
LibraryLocation="C:\Program Files\TortoiseHg\hg.exe"
Force="true"
Update="true"
LocalPath="$(SourcePath)"
/>
<HgUpdate
LibraryLocation="C:\Program Files\TortoiseHg\hg.exe"
Clean="true"
LocalPath="$(SourcePath)"
/>
I'm rather at a loss. Please let me know if you need any more information added to this post to solve this issue. I'm really quite new to MSBuild so really not sure where to start investigating this.
EDIT:
One thing i forgot to mention was that i have tried running the MSbuild command in a console window on the build server and still get the same result. This is really odd given it works fine in CCNet, what magic is CCNet doing to make this command work?
This is now resolved, unfortunately i'm not sure what changes i made to correct these. I believe it may have been down to path separators and whether they where trailing or not in another part of the config file. It does so annoy me with the lack of resilience/consistency between applications where you need to specify paths with/without trailing slashes.
Just a thought, but try adding 'C:\Program Files\TortoiseHg' to your system path. Maybe CCNet has it specified somewhere that Jenkins doesn't have access to.
Also, just for sanity's sake, verify that hg.exe actually exists at that location.
I am working with TS-7500 (ARM 9) board running Debian Linux (Linux ts7500 2.6.24.4). It is connected to a couple of sensors and is running driver code to talk to these sensors.
Every time the C program starts, it reads a couple of config-parameters from a config-file and starts sensors with those values.
So the task at hand is : presenting a web interface to show/edit these config-parameters to user. The task of the web interface can be summarized in four steps :
Read config-parameters from the config-file and show the current configuration
Allow user to change the configuration
Capture and save the changes to same config-file
These config-parameters could be presented as drop-down menu items or radio-buttons. And I have a linux background script which restarts the C prg when config-file is modified.
I know TS-7500 runs Tomcat. Now please suggest a good way to handle this problem. I have heard about using Servlet and JSPs (am not very familiar with those actually). Which one of them is suitable to generate HTML pages dynamically ? (as I see everytime I need to generate a new HTML page by selecting the current configuration while displaying the page).
Sorry for being very elaborate !
EDIT : Beeps ! No reply ? Come on guyz, is the question not clear ? Or no one has ever faced a similar problem (design problem) ??
The solution would be to use a PHP in addition with Apache web server ! PHP script could be used to
Read the config file and capturing the parameters
Generate a HTML form (by pre-selecting the dropdown menus and radio buttons from the already read parameters)
And capturing the new edits and saving them to config file.
PHP script must be placed in /var/www/ directory of the embedded board. Then from any system, it could be accessed just by keying the IP address of the board and the script name using a simple web browser.