I have created one SSIS package for data flow and its perfectly working fine for me (with my credentials). However, when its opened by another person with another login ID (credentials) its showing error:
Please see the below screenshot.Looks like its an access error. How can I give access so that anyone can open it.
The error I'm getting is :
the operation failed because the databse manager failed to access either the databse manager configuration file or the database configuration file.
There ware errors while loading the package. See the error list for details.
Error loading Package.dtsx. Failed to decrypt protected XML node "DTS:Password" with error 0x8009000B "Key not valid for use in specified satte. You may not be
authorized to access this information. This occurs when there is a cryptographic error. Verify that the correct key is available.
Upon searching on net. I think I can set "DontSaveSensitive". However,unable to find out how to do this? Whats are the steps I need to follow?
Link : https://learn.microsoft.com/en-us/sql/integration-services/security/access-control-for-sensitive-data-in-packages
How to resolve this?
Kudos for pinpointing issue. To solve it:
Open project solution from working credentials.
Right click on project.
Go to properties
Change the security level to DontSaveSensitive.
I've answered your question about unable to find out how to do this
Hope this works. Else come back here and we might suggest different approach.
Related
I am new to the Design Automation API, so please excuse and correct me if I am using the wrong terms. I am setting up the wiring for my very first Design Automation AppBundle, and I have almost all of it working. I followed the patterns in the "Delete Walls" tutorial.
I have a working add-in DLL that I can test locally and it runs under the "design.automation-csharp-revit.local.debug.tool".
I also have all of the Rest API connections setup, and I can successfully submit a WorkItem that will download a Revit file from a BIM 360, and start processing it in the sandbox of Design Automation. But I am getting an error during the execution on the sandbox where it seems it can't find my add-in file. Here is an excerpt from the WorkItem log:
[07/21/2020 18:02:26] Resolving location of Revit/RevitCoreEngine installation...
[07/21/2020 18:02:26] Running user application....
[07/21/2020 18:02:31] Cannot find the addin file:
[07/21/2020 18:02:31] Fail to deploy Addon DLL(s) in AppPackages.
[07/21/2020 18:02:31] RESULT: Failure
I have looked through "bundle" ZIP file many times looking for typos that could cause this, but I can't find anything, it looks identical to the "delete walls" example. So I'm wondering if there is somewhere else that I need to look. Or any other way I could debug this to find out were the connection is missing. I can only assume that the AppBundle and Activity items are setup correctly since I am getting this far and the error is not mentioning either of those items.
Any tips on where to look?
This turned out to be a misspelling of the [dot]bundle folder extension that triggered the issue.
I know there is similar question, but it didn`t helped me.
When I execute a package data flow task fails with the error:
"Unable to retrieve column information from the data source. Make sure your target table in the database is available."
I refreshed the source component, the destination components also. The table do exist in database. I tried with setting some parameters like "Always Use Default Code Page" to true but didn`t helped.
Connections are also ok.
Any idea?
Sounds like a permissions issue. Try, running Visual Studio as administrator or if that doesn't work, make sure your Windows Account has access to the data you require in SQL Server.
When I open a new simple SSIS Project I created I get an error:
'Error loading HyperionFlatLoads.dtsx: The connection "" is not found. This error is thrown by Connections collection when the specific connection element is not found.
C:\Users...\Projects\Hyperion_Load_Actuals\Hyperion_Load_Actuals\HyperionFlatLoads.dtsx
I've looked everywhere for this reference and can't for the life of me figure out what it's missing. The package runs fine; the data moves into the SQL table - but this error persists. Anyone want to help me find out why and eliminate this?
You can view and edit dtsx file as regular XML file. So, open it and find
<DTS:ConnectionManagers>
<DTS:ConnectionManager ... DTS:ObjectName="CM name">
if you are using SSIS 2012+
or
<DTS:ConnectionManager>
...
<DTS:Property DTS:Name="ObjectName">CM name</DTS:Property>
if you are on SSIS 2008.
Remove node <DTS:ConnectionManager> and save the file.
I want to add an alternative solution that I was facing for others who may stumble across this post.
I had setup logging, but forgot to specify a connection manager. This took me forever to find because viewing the XML doesn't make it obvious where "" is.
During packaging the Windows Store application, I get an unspecified error [APPX1204]:
C:\Program Files (x86)\MSBuild\Microsoft\VisualStudio\v11.0\AppxPackage\Microsoft.AppXPackage.Targets(1139,9): error APPX1204: Failed to sign 'D:\Projects\VS2012\Stroik\Stroik\AppPackages\Stroik_1.0.0.11_AnyCPU_Test\Stroik_1.0.0.11_AnyCPU.appx'. SignTool Error: An unexpected internal error has occurred.
Build output refers to the part of a file generated by VS2012:
<SignAppxPackage AppxPackageToSign="#(FinalAppxPackageItem)"
CertificateThumbprint="$(PackageCertificateThumbprint)"
CertificateFile="$(PackageCertificateKeyFile)"
HashUri="$(_HashUri)"
EnableSigningChecks="$(EnableSigningChecks)"
>
<Output TaskParameter="ResolvedThumbprint" PropertyName="ResolvedThumbPrint"/>
<Output TaskParameter="AppxPackagePublicKeyFile" PropertyName="AppxPackagePublicKeyFile" />
</SignAppxPackage>
Yesterday packaging proceeded successfully. Today I added aditional logic to my app and changed some data in manifest. Since then I'm reciving presented error. I tried to regenerate Certificate in Packaging menu, delete Store/Temporary Keys (then regenerate), ... much more but nothing helps.
Now I have no idea how to handle it. Furthermore packaging a new project (as it is provided by vs2012) results in the same error.
Have you got any suggestions how to solve it.
If it helps anyone else, I was trying to make the build on a network share (virtualizing windows). Creating it on the Windows partition solved the issue.
I was developing on a Virtual Machine in VirtualBox and tryed to publish to the shared folder.
Change the output folder to a local folder on the virtual maschine solved it.
Granted this is older - see if you can try it with a different live id
You could also try to generate a new app, and diff the manifests between the apps.
Now according to:
http://social.msdn.microsoft.com/Forums/en-US/toolsforwinapps/thread/f25939fb-c48c-4bd0-938e-6a0afbd2dca0/
you may want to sign out, use IE 'in safe private browsing' and create a new one.
Also ensure that IE is set in "Browsing History->Settings" to get a new version of the page every time.
Login with the new one and give it a try.
I'm not sure if this error is related here or not, but it's a starting point based on the prior feedback on the above post.
This japanese site lists the same error code and seems to have the same resolution as well
http://coelacanth.heteml.jp/blog/windows-8signtool-error-an-unexpected-internal-error-has-occurred/
Its worth a shot, but I'll admit on this one not being 100% sure, just trying to help out : )
How should a program handle errors? Example:
A program needs the file text.txt. It must exist and be writable. What should it do if it's not writable or doesn't exist? Should it try to chown/chmod the file? Should it try to create it or just display an error message?
Or: Should it try to find a solution or just display an error message?
It's up to you how to handle it. You have to define your scenarios, user interactions, and other parts of the program. Once you define those it is time to implement and test those scenarios.
Some questions to ask:
What data is being written to the file?
How critical is it that the data get saved?
If an error is reported, who will see the error?
If an error is reported, how do you expect a user to react? And what are their options?
I would go with Eilon's answer for the most part but would add the following caveat - I would not try to chown/chmod a file, unless you really need to i.e. if the purpose of your program is managing file permissions or acting as an installer of some sort. This is because a) your attempted chmod/chown may not work and b) your application should respect the user privileges with which it is run - if these are not sufficient you should inform the user via whatever mechanism you do this.
Your program should output an error on STDERR and return with an exit code different than zero.
For more informations :