SSIS - "There was an error while building." - ssis

does anyone had this issue before? When I try to build a Script Component in SSIS but get the following error:
This does not give any context and actually it never starts the building so I don't know what is this.

Related

There was an error while loading the package SSIS

I have created one SSIS package for data flow and its perfectly working fine for me (with my credentials). However, when its opened by another person with another login ID (credentials) its showing error:
Please see the below screenshot.Looks like its an access error. How can I give access so that anyone can open it.
The error I'm getting is :
the operation failed because the databse manager failed to access either the databse manager configuration file or the database configuration file.
There ware errors while loading the package. See the error list for details.
Error loading Package.dtsx. Failed to decrypt protected XML node "DTS:Password" with error 0x8009000B "Key not valid for use in specified satte. You may not be
authorized to access this information. This occurs when there is a cryptographic error. Verify that the correct key is available.
Upon searching on net. I think I can set "DontSaveSensitive". However,unable to find out how to do this? Whats are the steps I need to follow?
Link : https://learn.microsoft.com/en-us/sql/integration-services/security/access-control-for-sensitive-data-in-packages
How to resolve this?
Kudos for pinpointing issue. To solve it:
Open project solution from working credentials.
Right click on project.
Go to properties
Change the security level to DontSaveSensitive.
I've answered your question about unable to find out how to do this
Hope this works. Else come back here and we might suggest different approach.

The connection "" is not found. SSIS

When I open a new simple SSIS Project I created I get an error:
'Error loading HyperionFlatLoads.dtsx: The connection "" is not found. This error is thrown by Connections collection when the specific connection element is not found.
C:\Users...\Projects\Hyperion_Load_Actuals\Hyperion_Load_Actuals\HyperionFlatLoads.dtsx
I've looked everywhere for this reference and can't for the life of me figure out what it's missing. The package runs fine; the data moves into the SQL table - but this error persists. Anyone want to help me find out why and eliminate this?
You can view and edit dtsx file as regular XML file. So, open it and find
<DTS:ConnectionManagers>
<DTS:ConnectionManager ... DTS:ObjectName="CM name">
if you are using SSIS 2012+
or
<DTS:ConnectionManager>
...
<DTS:Property DTS:Name="ObjectName">CM name</DTS:Property>
if you are on SSIS 2008.
Remove node <DTS:ConnectionManager> and save the file.
I want to add an alternative solution that I was facing for others who may stumble across this post.
I had setup logging, but forgot to specify a connection manager. This took me forever to find because viewing the XML doesn't make it obvious where "" is.

nonfatal error in SSIS package from deleted Script Task

I am working in BIDS for 2008 R2
I have an annoying issue that I have not found the solution to yet. The error message is below. The line of code the error message refers to was from a Script Task that I deleted yesterday. My SSIS package executes fine and I am getting close to publishing the production version. I would like to clean up this non-fatal error first.
Would anyone have any suggestions on how to clear this up?
Thanks!
*Attempt to parse the expression "#[User::SS_Directory] +"''" + #["User::SS_InputFolderName] + "\" + #[User:SS_InputFileName]" failed and returned error code 0xC00470A6. The expression cannot be parsed. It might contain invalid elements or it might no be well-formed. There may also be an out-of-memory error.*
try
to rename the pkg and rebuild it, then rename back again.
check the connection manager
use format -> auto layout- diagram
open as text and lok for the string in the error
Mario

Flash Builder - Internal Build Error / Classes Must Not Be Nested

I've been working on a Flash Builder project for about a week and occasionally encounter one of these two errors when I build:
An internal build error has occurred. See the error log for more information.
1131: Classes must not be nested.
A quick Project > Clean fixes things up. When I opened my project this morning and tried to build it, I received the internal build error again. This time, however, Project > Clean results in 5 separate "Classes must not be nested" errors, all pointing to my main class declaration.
Running Project > Clean again leads back to the internal build error. If I Clean again, I get the 5 class errors again, and so on.
I'm using Flash Builder 4.6, Flex 4.6, and AIR 3.5. I haven't made any changes to my codebase since yesterday. Any ideas what might be causing this?
I had the same problem with flashb uilder 4.6,
when i try to compile the app out of the blue it says
"flash builder internal build error has occurred see the error log for more information"
to resolve this you have to check the compiler arguments
when this happens you wont be able to go to compiler argumnts GUI, you have to edit it in .actionScriptProperties file
remove -local and local names save the file and try to compile you would not get the error
to put back the local you have to rephrase the local as follows
-locale=en_US,us_EN
What worked for me was to remove all swc references from the project's compiler settings, then re-insert them.

Error in SSIS script component

I have a problem while executing a SSIS script component. To be honest I am learning SSIS and for the script component, I am going thru The Script Component as a Transformation Article. I have so far done whatever has been stated there . But while I am trying to execute the package, I am encountering the below error
TITLE: Package Validation Error
------------------------------
Package Validation Error
------------------------------
ADDITIONAL INFORMATION:
Error at Data Flow Task [Script Component [16]]: The script component is configured to pre-compile the script, but binary code is not found. Please visit the IDE in Script Component Editor by clicking Design Script button to cause binary code to be generated.
Error at Data Flow Task [DTS.Pipeline]: "component "Script Component" (16)" failed validation and returned validation status "VS_ISBROKEN".
Error at Data Flow Task [DTS.Pipeline]: One or more component failed validation.
Error at Data Flow Task: There were errors during task validation.
(Microsoft.DataTransformationServices.VsIntegration)
------------------------------
BUTTONS:
OK
------------------------------
A bit of googling reveals the following Package Validation Error . So after going thru that , I understood what is the cause of the problem but how to rectify that , I don't know. Moreover, debugging is not possible.
Please help me.
EDIT
At last I found out that the Precompiled Option should be set to FALSE. Default is TRUE. It solved the problem.
Thanks
Sometime is enough to rebuild the task, just edit it and build in vsta.
You typically get this error when some portion of your script is no longer functioning correctly. This is often due to a dependency in the script that is no longer valid. Why can't you debug the package? If this is not your package then you're going to have to find the person who wrote it and have them fix the errors.
We recently ran into this issue and discovered is was because our code was too modern. The person who wrote the script used some newer code candy like:
somestring = $"{somevariable}-{Someothervariable}"
SomeFunctionWithOutParameter(out bool myResult)
It looked fine in the VS2017 editor on my colleague's machines but for some reason when I edited the script it was being pulled up in VS2015 (SSIS was being edited in VS2017) and the code was flagged.
After reverting the code to older style using String.Format() and pre-declaring the out variable the script was able to compile and run.
My guess is that whatever is compiling the script task code is not using the latest and greatest c# compiler.